CBES-1000kg-003-000View Product
Force Sensors and Load Cell Sensors
Force Sensors detect and respond to the presence or a change in the amount of pressure on their actuator, which can be a ball, button, diaphragm, flat membrane, plunger, or pushbutton. The three sensor types are force sensing resistor, load cell, and resistive. Their operating force ranges covering 0 to 1500 newtons (N), 0 to 22,680 kilograms force (kgf) or 0 to 50,000 pounds (lbs.), with output options of analog voltage, resistive, ratiometric, and voltage.
Load Cell Sensor: Features and Specifications
- Function in the design. A load cell converts applied force into a measurable electrical signal, often through a strain-gauge bridge. Start with the role the component plays in the measurement assembly. Match the force direction, rated capacity, overload limit and signal conditioning. An IrDA transceiver combines an infrared emitter and receiver for a defined data link. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- 050-1196-02 at a glance. The catalog description reads “LOAD BUTTON WITH 3/8-24 UNF”. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. The catalog description reads “LOAD BUTTON WITH 1/2-20 UNF”. When comparing force sensors, load cells, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Force Sensor: Applications and Design Considerations
- Typical operating conditions. It measures weight, compression or tension in scales and test fixtures. For this use, specify the physical quantity of interest, expected range, response time and influence of the mounting arrangement. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The catalog description reads “LOAD BUTTON WITH 1/2-20 UNF”. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The catalog description reads “LOAD BUTTON WITH 1-14 UNF”. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Test the complete measurement path, including mounting and signal conditioning. A repeatable reading at one point does not establish accuracy across the full range. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the force sensors, load cells check, match the force direction, rated capacity, overload limit and signal conditioning. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Load-Cell
- Define the acceptance criteria. Match the force direction, rated capacity, overload limit and signal conditioning. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include manufacturer description, package and ordering designation. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The catalog description reads “LOAD BUTTON WITH 1-14 UNF”. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. Read the notes attached to any rating used in your decision. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required force sensors, load cells by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the measurement assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.