Common Mode Chokes
A common mode choke is an electrical filter that blocks high frequency noise common to two or more data or power lines while allowing the desired DC or low-frequency signal to pass. Common mode (CM) noise current is typically radiated from sources such as unwanted radio signals, unshielded electronics, inverters and motors. Left unfiltered, this noise presents interference problems in electronics and electrical circuits.
Common Mode Chokes: Features and Specifications
- Function in the design. A common mode choke couples windings so that common-mode current sees a high impedance. Start with the role the component plays in the signal path. Check common-mode impedance at the noise frequency, differential loss and winding current. RF filters are specified by their passband, stopband and insertion loss. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- 47700 at a glance. The listing for 47700 gives filter type as Power Line, number of lines as 2, current rating (max) as 14A. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For current rating (max), 47700 is listed as 14A and 47701 as 13A. When comparing common mode chokes, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Common Mode Choke Coil: Applications and Design Considerations
- Typical operating conditions. It reduces interference on paired signal lines and power inputs. For this use, specify wanted bandwidth, unwanted frequency components and the impedances on either side of the filter. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for 47701 gives number of lines as 2, current rating (max) as 13A, dc resistance (dcr) (max) as 8mOhm. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for 47702 gives operating temperature as -25°C ~ 125°C, mounting type as Through Hole, size / dimension as 1.417" L x 0.866" W (36.00mm x 22.00mm). For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Compare the response with the intended source and load. A laboratory insertion loss curve depends on the fixture and its termination. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the common mode chokes check, check common-mode impedance at the noise frequency, differential loss and winding current. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Common Mode Inductor
- Define the acceptance criteria. Check common-mode impedance at the noise frequency, differential loss and winding current. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include filter type, number of lines, current rating (max), dc resistance (dcr) (max). Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for 47702 gives current rating (max) as 12A, dc resistance (dcr) (max) as 9.2mOhm, operating temperature as -25°C ~ 125°C. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For dc resistance (dcr) (max), the respective entries for 47701 and 47702 are 8mOhm and 9.2mOhm. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required common mode chokes by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the signal path, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.