Product categories

AC DC Converters

AC-DC Converters

An device that converts an alternating current voltage input to a direct current voltage level output.

Screen Default Ranking Price By Date

Features of AC-DC Converters

  • Function in the design. A board-mount AC-DC converter accepts an AC input and supplies one or more DC rails. Start with the role the component plays in the power rail. Check the applicable input range, isolation approvals, output load and cooling conditions. A related catalog entry helps explain the distinction. Board-mount supplies package power conversion around a defined footprint and pinout. Compare the role of each in the assembly before choosing between the two categories; a similar name does not necessarily describe the same job.
  • 1.5E100-230 at a glance. The listing for 1.5E100-230 gives type as Enclosed, number of outputs as 1, voltage - input as 210 ~ 250 VAC. Read these entries together with the manufacturer’s description. They belong to this ordering code; another device in the same family can have a different implementation. Open the product record before copying a value into a bill of materials, and retain the units and any qualifiers alongside the number so that a later comparison uses the same definition.
  • Differences within the range. For current - output (max), 1.5E100-230 is listed as 1A and 1.5E25-230 as 250mA. When comparing ac dc converters, distinguish a property shown for an individual model from a requirement shared by the whole design. Two rows can appear similar when only their short descriptions are visible. Look at the full entry, then use the manufacturer’s drawing or characteristic table to resolve any difference that would affect assembly, operation or the acceptance test.

Applications of AC-to-DC Converters

  • Typical operating conditions. It powers embedded equipment with an internal mains-to-board supply. For this use, specify input extremes, load steps, startup current and the heat that can leave the board. Write down the condition that matters to the finished equipment before narrowing the list of parts. A prototype that works at a single bench setting can still miss the requirement when installed. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for 1.5E25-230 gives number of outputs as 1, voltage - input as 210 ~ 250 VAC, voltage - output 1 as 1.5V. In an application review, mark which of these properties the surrounding design fixes and which can still change. A second catalog example gives another point of comparison. The listing for 1.5E250-230 gives current - output (max) as 2.5A, operating temperature as -20°C ~ 71°C, mounting type as Through Hole. When the design has to fit an established interface, use the documentation for that interface alongside the product record, and resolve discrepancies before committing the layout or ordering evaluation quantities.
  • Checks on the prototype. Measure at the load as well as the module pins. Cabling, copper resistance and output capacitance influence the transient voltage the load actually sees. Record the setup, the operating conditions and the observed result so another engineer can repeat the check. For ac dc converters, pay particular attention to the requirement behind this selection guidance: check the applicable input range, isolation approvals, output load and cooling conditions. If the result is marginal, change one condition at a time and compare it with the original measurement before attributing the difference to the component.

How to Choose AC-DC Converters

  • Define the acceptance criteria. Check the applicable input range, isolation approvals, output load and cooling conditions. Put the nonnegotiable requirements in a short comparison table before looking at price. For this category, useful starting columns from the catalog include type, number of outputs, voltage - input, voltage - output 1. Give each critical value a unit and an acceptable range. Where a catalog entry leaves a field blank, flag it for confirmation in the datasheet rather than assigning a value from another member of the family.
  • Compare exact ordering codes. The listing for 1.5E250-230 gives voltage - input as 210 ~ 250 VAC, voltage - output 1 as 1.5V, current - output (max) as 2.5A. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For size / dimension, the respective entries for 1.5E25-230 and 1.5E250-230 are 2.30" L x 1.80" W x 1.00" H (58.4mm x 45.7mm x 25.4mm) and 3.53" L x 2.53" W x 2.06" H (89.7mm x 64.3mm x 52.3mm). Check which of these values the assembly drawing or design specification requires. A typical value measured under one set of conditions is a poor acceptance limit unless the manufacturer also specifies the relevant guarantee under your operating conditions.
  • Prepare the purchase specification. For a quotation, identify the required ac dc converters by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Include quantity, delivery requirements and any packaging constraint imposed by the assembly process. Before approving an alternative for the power rail, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
Add ComparisonUp to 4 can be added

    Recommended Products