High Frequency (RF) Relays

RF Relays

High frequency and RF (radio frequency) relays are high switch speed, high reliability and RF insulated relays designed for use in computers, testing equipment and radio broadcast systems. Additional features may include an internal diode, magnetic shielding and hermetic seals. These surface mount and through-hole relays are differentiated by operate and release time, coil current and contact rating. Contact forms include DPDT, SPDT and SPST configurations.

Screen Default Ranking Price By Date

RF Relays: Features and Specifications

  • Function in the design. An RF relay is characterized for switching high-frequency signal paths. Start with the role the component plays in the switching assembly. Check insertion loss, isolation, impedance and switching lifetime in band. A solid state relay switches an output electronically and may exhibit off-state leakage. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
  • 2200-2302 at a glance. The listing for 2200-2302 gives coil type as Non Latching, coil current as 33.3 mA, coil voltage as 5VDC. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
  • Differences within the range. For coil current, 2200-2302 is listed as 33.3 mA and 2204-05-421 as 13.5 mA. When comparing high frequency (rf) relays, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.

RF Relays: Applications and Design Considerations

  • Typical operating conditions. It routes test signals or switches radio front-end paths. For this use, specify control signal, load waveform, switching frequency and the required state when control power is removed. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for 2204-05-421 gives coil current as 13.5 mA, coil voltage as 5VDC, contact form as SPST-NO (1 Form A). Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for 2204-12-321 gives contact rating (current) as 500 mA, switching voltage as 200VAC, 200VDC - Max, must operate voltage as 9 VDC. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
  • Checks on the prototype. Check the load type used for the published rating. A resistive load, an inductive load and a capacitive input impose different stresses during switching. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the high frequency (rf) relays check, check insertion loss, isolation, impedance and switching lifetime in band. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.

Selection Criteria for RF Relays

  • Define the acceptance criteria. Check insertion loss, isolation, impedance and switching lifetime in band. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include coil type, coil current, coil voltage, contact form. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
  • Compare exact ordering codes. The listing for 2204-12-321 gives coil voltage as 12VDC, contact form as SPST-NO (1 Form A), contact rating (current) as 500 mA. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For must release voltage, the respective entries for 2204-05-421 and 2204-12-321 are 0.4 VDC and 1 VDC. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
  • Prepare the purchase specification. For a quotation, identify the required high frequency (rf) relays by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the switching assembly, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.