N25SP1R5L-FView Product
Inrush Current Limiters
Inrush Current Limiters (ICL) are designed to limit an initial large flow of electric charge that occurs when a device is first turned on. The Current steady state max range is from 100 mA to 80 A with the Resistance at Current ranging from 1 mOhms to 30.3 Ohms and a lead spacing range of 0.098” to 1.378”.
Inrush Current Limiters: Features and Specifications
- Function in the design. An inrush limiter controls the current surge when an input capacitor first charges. Start with the role the component plays in the protected branch. Check cold resistance, continuous current and how quickly the equipment may restart. A metal oxide varistor has a nonlinear voltage-current characteristic and absorbs surge energy. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
- B57127P100M301 at a glance. The listing for B57127P100M301 gives r @ 25°c as 10 Ohms, tolerance as ±20%, current - steady state max as 9:00 AM. These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
- Differences within the range. For r @ 25°c, B57127P100M301 is listed as 10 Ohms and B57127P109M301 as 1 Ohms. When comparing inrush current limiters (icl), distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.
Inrush Limiter: Applications and Design Considerations
- Typical operating conditions. Common placements include AC supply inputs and bulk DC capacitor banks. For this use, specify normal operating current, expected disturbances and the maximum stress the downstream equipment can tolerate. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
- Integration example. The listing for B57127P109M301 gives tolerance as ±20%, current - steady state max as 22 A, r @ current as 13 mOhms. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for B57127P209M301 gives diameter as 1.201" (30.50mm), lead spacing as 0.295" (7.50mm), approval agency as UL. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
- Checks on the prototype. Distinguish a transient event from a sustained fault. Check the manufacturer’s stated test waveform and the device condition after the event. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the inrush current limiters (icl) check, check cold resistance, continuous current and how quickly the equipment may restart. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.
Selection Criteria for Inrush Current Limiters
- Define the acceptance criteria. Check cold resistance, continuous current and how quickly the equipment may restart. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include r @ 25°c, tolerance, current - steady state max, r @ current. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
- Compare exact ordering codes. The listing for B57127P209M301 gives current - steady state max as 16 A, r @ current as 22 mOhms, diameter as 1.201" (30.50mm). Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. For r @ current, the respective entries for B57127P109M301 and B57127P209M301 are 13 mOhms and 22 mOhms. Check which of these values the assembly drawing or design specification requires. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
- Prepare the purchase specification. For a quotation, identify the required inrush current limiters (icl) by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the protected branch, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.
ChipApex | Global Electronic Components Supplier