Product categories

Magnetic, Reed Switches

Magnetic Reed Switches

Magnetic reed switches are devices consisting of a pair of ferromagnetic flexible metal reed contacts in a hermetically sealed glass, magneshere, or other molded body and are operated by an applied magnetic field. The contacts are normally open, closing when a magnetic field is present, or closed and open when a magnetic field is applied. The switch may be actuated by an electromagnetic coil or permanent magnet placed near the switch. When the magnetic field is removed, the reeds return to their original position. Contact forms include SPDT and SPST.

Screen Default Ranking Price By Date

Magnetic Reed Switches: Features and Specifications

  • Function in the design. A reed switch changes contact state in response to a magnetic field. Start with the role the component plays in the operator interface. Check sensitivity, orientation, contact load and the field at the intended air gap. A keypad switch groups selectable keys into a defined contact or matrix arrangement. On the assembly drawing, identify which part performs each function. That distinction is useful when two catalog categories have similar names.
  • 2230-1901-900 at a glance. The listing for 2230-1901-900 gives type as Glass Body Reed, circuit as SPST-NC, current - switching as 1A (AC/DC). These values apply to this ordering code. Check the manufacturer’s description before carrying them over to another member of the family. When you enter a rating in the bill of materials, copy its unit and the conditions attached to it. That gives the next engineer enough information to compare another part on the same basis.
  • Differences within the range. The listing for 2450-1901-900 gives current - switching as 1A (AC/DC), voltage - switching ac as 150 V, voltage - switching dc as 150 V. When comparing magnetic, reed switches, distinguish a property shown for an individual model from a requirement shared by the whole design. Short descriptions often omit the detail that decides whether a part fits. Check the drawing for differences that affect assembly. For differences in operation, find the corresponding row in the manufacturer’s characteristic table and read the test conditions.

Reed Switch: Applications and Design Considerations

  • Typical operating conditions. It detects closure or position without a mechanical linkage to the moving target. For this use, specify actuation method, contact arrangement, available travel and clearance around the moving parts. Write down the conditions at the installation site. If the bench setup reproduces only one of them, record what still needs testing in the assembled equipment. Include at least one representative operating case and the most demanding credible case in the comparison.
  • Integration example. The listing for 2450-1901-900 gives circuit as SPST-NC, current - switching as 1A (AC/DC), voltage - switching ac as 150 V. Which of those values does the existing design fix? Mark those first. The remaining values give you room to consider another part. The listing for 2451-1901-900 gives voltage - switching dc as 150 V, power - rated as 20W, operate time as 2 ms. For an existing interface, place its drawing next to the product record. Resolve any discrepancy while the layout can still change and before ordering parts for evaluation.
  • Checks on the prototype. Check the contact state in every operating position. The appearance of an actuator alone does not establish whether a contact is momentary or maintained. Record how the part was installed and what you observed. Include the operating conditions so someone else can repeat the measurement. During the magnetic, reed switches check, check sensitivity, orientation, contact load and the field at the intended air gap. If the reading is near the limit, repeat the original measurement. Then vary one condition at a time to see whether the component or the setup accounts for the difference.

Selection Criteria for Magnetic Reed Switches

  • Define the acceptance criteria. Check sensitivity, orientation, contact load and the field at the intended air gap. Set a pass or fail limit for each critical requirement before comparing prices. For this category, useful starting columns from the catalog include type, circuit, current - switching, voltage - switching ac. Give each critical value a unit and an acceptable range. A blank field leaves an open question. Check the datasheet for that particular ordering code before entering a value in the comparison table.
  • Compare exact ordering codes. The listing for 2451-1901-900 gives current - switching as 1A (AC/DC), voltage - switching ac as 150 V, voltage - switching dc as 150 V. Check the complete manufacturer part number, including suffixes, against the ordering table for the device you intend to buy. Read the notes attached to any rating used in your decision. If the table gives only a typical value, look for a guaranteed limit at your operating conditions. The typical figure alone gives you little basis for rejecting a delivered part.
  • Prepare the purchase specification. For a quotation, identify the required magnetic, reed switches by manufacturer and complete part number. If alternatives are acceptable, state which differences require engineering approval. Tell purchasing how many pieces you need, when they must arrive and which packing formats the assembly line can accept. Before approving an alternative for the operator interface, compare it against the same acceptance criteria used for the original part and keep the comparison with the released bill of materials.